What is the installation pressure of the thyristor of an induction melting furnace?
What is the installation pressure of the tyrystor of an induction melting furnace?
Pressure: The pressure referred to here is the installation pressure of the thyristor. The correct installation pressure of thyristor for intermediate frequency diathermy furnace: 150-200KG/cm2. When the intermediate frequency diathermy furnace leaves the factory, the installation of the thyristor is generally carried out by a hydraulic press. Manually using an ordinary wrench with a large amount of force cannot reach this value, so when pressing manually, there is no need to worry that the silicon will be crushed; if the pressure is loosened, the silicon will be burned due to poor heat dissipation.