Thick-walled steel pipe anticorrosive heating equipment
Thick-walled steel pipe anticorrosive heating equipment
The anti-corrosion heating equipment for thick-wall steel pipes is highly energy-efficient, environmentally friendly, and has high production efficiency. The whole set of anti-corrosion heating equipment for thick-wall steel pipes is controlled by PLC fully automatic and intelligently, and the operation is simple. High-quality thick-walled steel pipe anticorrosive heating equipment can be customized for you according to different processes of users.
Features of thick-walled steel pipe anti-corrosion heating equipment:
★Intermediate frequency power control, infrared thermometer control, non-contact heating, make the workpiece heated more evenly.
★Closed loop control, fast heating speed and high production efficiency.
★All water pipes of the induction furnace body are made of 304 stainless steel pipes to avoid water rust and scale. The cooling effect is greatly improved and the service life is long.
★The man-machine interface PLC control system is adopted, and the whole touch screen controls the production of the whole set of equipment.
★High temperature control accuracy, automatic intelligent control.
★No pollution, low energy consumption, no cracks on the processed workpiece, and the linearity of toughness and tensile strength can meet customer satisfaction requirements.
★The conveying and output system of the thick-walled steel pipe anticorrosive heating equipment is controlled by an independent frequency converter, the cylinder is automatically controlled, and the running speed is controlled in sections.
★Professional formula management system, after selecting the steel grade and plate type parameters to be produced, the relevant parameters are automatically called.
★It is equipped with a closed cooling tower for cooling, which is energy-saving and environmentally friendly.
Operating conditions of thick-walled steel pipe anticorrosive heating equipment and user-supplied parts:
1. Gee hoë spanning aan die primêre kant van die transformator.
2. Hoogte: ≤2000m; Relatiewe humiditeit: ≤90%
3. The anti-corrosion heating equipment of thick-walled steel pipes must be grounded: it is recommended to use galvanized pipes to be driven into the ground and be reliably connected to the equipment. The connecting wires use more than 10 flat copper wires. The power supply, furnace body and operation table are all separately set with ground wires.
4. Equipment cooling (according to the user’s site, there will be dedicated technical personnel for on-site guidance)
5. User-supplied transformer oil.