Анализ на повредата на машина за високочестотно охлаждане

Анализ на отказите на High Frequency Quenching Machine Tool

Common fault analysis and elimination of primary and secondary short circuits of high frequency quenching machine tool transformers:

(1) Cause analysis of high frequency quenching machine tools

and inductive load circuits. When such a fault occurs, there is a fire between the primary and secondary of the transformer, and in severe cases, water leakage occurs in the primary or secondary. Since the short-circuit points appear in different parts of the primary and secondary, once the main contactor is turned on, the generator working curve may appear in different inductive curve positions, so the response of the instrument is different, but basically G is greatly reduced, /> Cos Xu is perceptual, falling, and both 1GL and 1GJ2 act.

(2) Fault diagnosis of high frequency quenching machine tools

Първичното или вторичното водоснабдяване на трансформатора не е гладко или блокирано, което води до нагряване на намотката, разрушаване на първичната изолация и образуване на първично и вторично късо съединение.

Този вид повреда се открива лесно по обгорената намотка или мястото на изтичане и след това може да се прецени чрез измерване на електрическото съпротивление на лампата или мултиметъра.