- 18
- Sep
18 uses of epoxy glass fiber rod
18 uses of epoxy glass fiber rod
Las varillas de fibra de vidrio epoxi también se conocen comúnmente como varillas de tracción. Las varillas con secciones circulares formadas por prensado en caliente de moldes de conformado tienen altas propiedades mecánicas y dieléctricas y son adecuadas para estructuras aislantes en motores y equipos eléctricos. Componentes, y se puede utilizar en ambientes húmedos y aceite de transformador; generalmente utilizado para pararrayos o varillas de núcleo aislante.
1. Epoxy glass fiber rods are used as structural parts in motors and electrical appliances, and their requirements are very different. According to their own insulation strength requirements, different epoxy glass fiber rods can be selected to make the demander better and more assured Choose a suitable product!
2. Square bakelite rods are commonly known as pull rods. The rods with round cross-sections formed by hot pressing of forming molds have high mechanical and dielectric properties and are suitable for insulating structures in motors and electrical equipment. Components, and can be used in humid environments and transformer oil; generally used for lightning arresters or insulator core rods.
3. The density is greater than 2.0g/cubic centimeter;
4. La resistencia a la flexión es inferior a 320Mpa;
5. The compressive strength is greater than or equal to 200 Mpa;
6. La resistencia al corte es mayor que 32Mpa;
7. Dielectric constant 3-6;
8. El factor de pérdida dieléctrica (50 Hz) es mayor o igual a 0.02;
9. Volume resistivity 1. In normal state, it is greater than or equal to 1.0*10 to the 11th power ohm, and when immersed in water, it is greater than or equal to 1.0*10 to the 9th power ohm;
10. Parallel layer insulation resistance 1. Normally, it is greater than or equal to 1.0*10 to the 11th power ohm, and when immersed in water, it is greater than or equal to 1.0*10 to the 9th power ohm;
11. Tensión soportada en superficie (tensión soportada en el aire durante 1 minuto, con un intervalo de 30 mm) 14 kV;
12. Tensión soportada en la dirección de la capa vertical (tensión soportada en aceite de transformador a 90 + -2 grados Celsius durante 5 minutos) 18-20 kV;
13. Parallel layer direction withstand voltage (withstand voltage in transformer oil at 90+-2 degrees Celsius for 5 minutes, with an interval of 25mm);
14. The insulation resistance is greater than or equal to 5*10 to the 4th power ohm;
15. Power frequency withstand voltage: the distance between the oil compartment of the on-load tap-changer and the ground (withstand voltage in the transformer oil, 100mm. 5 minutes) between phases (according to customer technical requirements) is greater than 85 kV.
16. Las especificaciones del modelo se pueden personalizar según los requisitos.
17. Square rods can be processed by large cutting machines, and round rods can be processed by washing machine!
18. Reinforced insulating rods can better meet customer needs!