induction melting furnace working principle – parallel resonance

four de fusion par induction working principle – parallel resonance

frequency power supply

The power supply of the induction melting furnace adopts the parallel resonance puissance de fréquence intermédiaire supply, which is the earliest application of intermediate frequency power supply in China. It is a frequency conversion device that converts three-phase power frequency AC electrical energy into single-phase intermediate frequency electrical energy. Its advantage is that it has strong load adaptability and can be used as the power supply for four de fusion par induction .

Figure 2-1 shows the principle diagram of the main circuit of the parallel resonant intermediate frequency power supply, which is mainly composed of isolating switch (DK), AC contactor (or electric circuit breaker KM), incoming line inductance (L1 ~ L3), and fast coupler ( FU), rectifier (VT1 ~ VT6), smoothing reactor (LF), inverter (VT7 ~ VT10), parallel resonant load (L, C) . The rectifier converts the three-phase power frequency alternating current into direct current; the smoothing reactor is used to filter the rectified current ripple and isolate different ripple voltages between the rectifier and the inverter; the inverter converts the direct current into a single-phase intermediate frequency Alternating current; the parallel resonant load composed of an inductor and a compensation capacitor can better adapt to the change of load properties during the heating process.

Figure 2-1 Parallel resonance intermediate frequency power supply main circuit

( 1) Three-phase bridge-type fully-controlled rectifier circuit The rectifier circuit of the parallel resonant intermediate frequency power supply adopts a three-phase bridge-type fully-controlled rectifier circuit. The principle is shown in Figure 2-2. Since the smoothing reactor (LF) has a large inductance and the load is an inductive load, the load current output by the rectifier is continuous and a straight line. When aW60° , the output waveform of the rectifier circuit is the same as that of the resistive load, and the conduction law is the same as that of the resistive load. When a>60° , due to the effect of the inductor LF , the thyristor will still be turned on after the power supply voltage crosses zero, until the next thyristor is triggered to turn on, so that a negative area appears in the waveform of the rectifier output voltage, but the rectifier output current is still One level

 

Wire. When the control angle increases to 90. When the positive and negative areas in the output voltage waveform are equal, the average value of the output voltage Ud=0. When a>90° , the rectifier circuit works in the active inverter working state. The phase shift range of the rectifier circuit of the intermediate frequency power supply is 0°~150°.

( 2) Inverter circuit Figure 2-3 is a schematic diagram of the parallel inverter circuit. The capacitor C in the load circuit is connected in parallel with the inductor coil L , and the commutation is based on the principle of parallel resonance, so it is called a parallel resonance inverter circuit. The DC voltage Ud provided by the thyristor fully-controlled rectifier circuit is continuously adjustable, and the parallel inverter circuit inverts the DC power into an intermediate frequency AC power supply to the load. The DC side string has a large filter inductance LF, so it is a current-type inverter. Because the operating frequency is relatively high, the thyristors of the 4 bridge arms of the inverter circuit adopt fast thyristors. L7 ~ L10 are the commutation inductance of the inverter thyristor, which is used to limit the current rise rate of the thyristor during commutation.

 