- 11
- Apr
What should be paid attention to when using inclined tube furnace?
What should be paid attention to when using inclined four tubulaire?
a. The gas supply of the tube furnace should be stopped immediately in the following situations:
1. The pressure of the gas main pipe drops below 2500pa, or the pressure fluctuation of the main pipe endangers safe heating.
2. The flame in the furnace goes out suddenly.
3. The suction power of the chimney drops, and heating cannot be guaranteed.
4. The furnace tube leaks oil and gas.
5. Suddenly smoke.
b. Before the tube furnace is ignited, the wall of the furnace must be cleaned with steam, and the gas must be turned on after ignition. It is strictly forbidden to ignite the gas first to avoid explosion.
c. It is strictly forbidden to ignite the furnace without steam cleaning.
d. It is strictly forbidden to ignite the gas first to avoid explosion.
e. There must be more than two persons when the tube furnace is ignited.
f. When the tube furnace is shut down for maintenance, it must be fully cleaned with steam to ensure that the gas is driven out.
g. Only when the washing oil circulation volume is normal, can the tube furnace be fired and heated.