site logo

The treatment method of the water temperature rise of the induction heating power supply

The treatment method of the water temperature rise of the Endiksyon chofaj ekipman pou pouvwa

1. Turn off the power supply, only connect the water but not the electricity, exchange the water inlet and outlet, and then rush the water vigorously, back and forth several times, so that the blockage inside can be quickly cleaned;

2. Filter with a filter at the inlet of the circulating water to prevent solids or other things from entering the circulating water;

3. If conditions permit, we recommend that the sensor be circulated by a separate way of water, so that some large solids will not block the small sensor water nozzle;

The above three tips are common ways to deal with rising water temperature, and they can be effective immediately. If you have tried all the above three methods and the water temperature alarms, then there are two more steps to check: 1. Whether the power of your pump is too small; 2. In the circulating water, whether there is a broken or blocked pipe, the above is the method.