site logo

Solution for startup steps of high frequency induction heating equipment

Solution for startup steps of high frequency induction heating equipment

1. According to the size of the workpiece, select and install the appropriate sensor.

2. Connect the cooling water, and check the flow and pressure of the cooling water. If there is any abnormality, it should be checked.

3. Turn on the power supply, the power supply is three-phase three-wire 380V, and the chassis should be grounded reliably.

4. Press the control switch on the front panel and turn on the control power. At this time, the power indicator on the panel should be on.

5. Wait for about 5 seconds, when you hear the “click” of the relay in the cabinet, you can start the heating operation.

6. Put the work into the sensor, and use the remote control switch or the manual heating start button on the panel to heat it. When the requirements are met, disconnect the remote control switch or the panel heating and shut down.

7. When the work is completed, the heating operation is to be stopped. After selecting the “control switch” of the panel to turn off the host, turn off the air switch of the power distribution panel.