The calculation method of the holding time of the workpiece in the experimental electric furnace
The calculation method of the holding time of the workpiece in the 実験用電気炉
For the heat treatment of the workpiece in the experimental electric furnace, the commonly used formula for calculating the holding time is t=α·K·D
どこ:
t——Holding time (min);
α——heating coefficient (min/mm);
K——The correction coefficient when the workpiece is heated;
D——The effective thickness of the workpiece (mm).