- 20
- Sep
Induction furnace power calculation method
Induction furnace power calculation method
1. Induction heating furnace power calculation P=(C×T×G)÷(0.24×S×η)
Note for induction furnace:
1.1C= specific heat of material (kcal/kg℃)
1.2G=workpiece weight (kg)
1.3T=Heating temperature (℃)
1.4t=time (S)
1.5η= heating efficiency (0.6)
2. Induction furnace quenching power calculation P=(1.5—2.5)×S2.1S=the area of the workpiece to be quenched (square centimeters)
3. Calculation of induction melting furnace power P=T/23.1T=electric furnace capacity (T)
4. Frequency calculation of coreless induction furnace δ=4500/d2
4.1 4500=Coefficient
4.2 d=workpiece radius