1. Before starting the machine, it is necessary to check whether the main control cabinet, transformer and sensor are connected to water. And check whether the waterway is blocked. It is strictly forbidden for the machine to work in the absence of water.

2. Before closing the air switch, check whether the power button is up (up means off). Before pressing the power button, make sure that the start button is up (up means stop), and make sure that the power adjustment button is turned to the minimum.

3. Before starting the machine, you must check whether the sensor is short-circuited. It is strictly forbidden to start the machine when the sensor is short-circuited. It is strictly forbidden to start the equipment with no load and high power.

4. After the sensor is put into some workpieces when the machine is turned on, start the machine and slowly turn the power adjustment knob to the desired position.

5. Make sure that the workpiece in the sensor is not less than half when it is turned off, and turn the power adjustment knob to a small correspondingly. The shutdown sequence should be to turn the power adjustment button to the minimum first, then the start button is up (stop), and finally the power button is up (off). It is strictly forbidden to directly turn off the power button in the case of high power output.

6. After the equipment is turned off, the cooling water should continue to cool for more than 20 minutes to ensure that the equipment is completely cooled.

7. It is strictly forbidden for the machine to push out all the hot materials in the sensor when the power adjustment button is at the 7 to the maximum position in the startup state (causing the machine to output high power no-load).

8.Dust the inside of the equipment in one month, and descale the cooling system of the equipment with a descaling agent in 3 months. Depending on the water quality, the descaling time can be shortened.