site logo

The importance of the coil of induction heating furnace with water

The importance of the coil of induction heating furnace with water

cuptor de încălzire prin inducție coil is usually water-passed, and the heat generated by it is mainly taken away by water cooling. Therefore, there must be sufficient water flow and water pressure to ensure that the copper pipe of the sensor flows through the necessary amount of water. Therefore, the working pressure of the cooling water should not be less than 0.2~0.3Mpa, the inlet water temperature should be less than 35℃, and the outlet water temperature should be less than 55℃. If the water pressure is not enough, it will cause the inductor coil to vaporize and heat up. If it is not found in time, the copper pipe will break and water will overflow. And the sensor is under high temperature working conditions, at this time, it is likely to explode, so the sensor water cooling is extremely important

.