Common fault table of rectifier circuit of induction melting furnace
- 28
- korrik
- 28
- korrik
Common fault table of rectifier circuit of furrën e shkrirjes me induksion
| No DC voltage | Rectified trigger without pulse output | Rectifier trigger regulated power supply without voltage output |
| Poor contact of rectifier trigger board | ||
| Whether the synchronous transformer is damaged or welded | ||
| Turn off the power potentiometer | ||
| The blocking protection in the regulation system is damaged | ||
| DC voltage is low | Individual rectifier bridge arm KP tube has no trigger pulse | Poor contact of the connector or cause desoldering |
| Partial rectifier trigger without pulse output | ||
| The rectifier pulse transformer is damaged:
Pulse transformer wire disconnected Short circuit of pulse transformer secondary diode |
||
| Some KP tubes have high trigger power | ||
| Some KP tubes or couplers are damaged | ||
| Poor contact of main circuit contactor or air switch (knife switch) | ||