How to check the water cooling system of induction melting furnace?

How to check the water cooling system of induction melting furnace?

After the water circuit of the ukuchithwa kwesithando somlilo is connected, use a 0.4Mpa water pressure test for 10 minutes to check for water leakage. After qualified, adjust the electric contact pressure gauge to the range of 0.15~0.25Mpa. Adjust the signal thermometer to 55°C. Check whether the current branch is normal.