site logo

is the power of the induction melting furnace distributed?

is the power of the induction melting furnace distributed?

The power distribution ratio of the induction melting furnace is as follows, for your reference.

The power distribution ratio of the induction melting furnace :

project Power consumption (kw.h/t) Proportion to total power (%)
total power 1000 100
billet 650 65
sensor 300 30
transformer 20 2
capacitor 5 0.5
Others (rails, etc.) 25 2.5

If the induction melting furnace is divided as a whole, the proportion of effective heating power generally accounts for 60%, and the proportion of ineffective heating power accounts for 40% . Power thyristors, reactors, capacitors, induction coils and other components are generated, and they will be taken away by cooling water.