- 05
- Sep
What are the technical parameters of the 2.0T induction melting machine 1000 KW ?
What are the technical parameters of the 2.0T induction melting machine 1000 KW ?
| project | unit | data | Remark |
| Electric furnace parameters | |||
| Rated Capacity | t | 2.0 | Liquid steel |
| Maximum capacity | t | 2.3 | Liquid steel |
| Maximum working temperature | °C | 1750 | |
| Lining thickness | mm | 120 | |
| Induction coil inner diameter φ | M m | 840 | |
| Induction coil height | mm | 1380 | |
| Electrical parameters | |||
| Transformer capacity | KVA | 1000 | |
| Transformer primary voltage | KV | 10KV | |
| Transformer secondary voltage | V | 660, 660 | 12-pulse dual output |
| Rated power of intermediate frequency power supply | KW | 1000 | 12-pulse dual input |
| Rated input current | A | 955 | |
| DC voltage | V | 890 | |
| DC | A | 1120 | |
| Conversion efficiency | % | 9 6 | |
| Startup success rate | % | 100 | |
| The highest output voltage of the intermediate frequency power supply | V | 2000 | |
| Rated working frequency | Hz | 500 | |
| Power conversion efficiency | % | 96 | |
| Working noise | db | ≤75 | |
| Comprehensive parameters | |||
| Melting rate (heating to 160 0℃) | T/h | 1.72 | The time used to melt a furnace is related to the charging |
| Melting power consumption (heating to 160 0℃) | kW.h/T | 560 | |
| Hydraulic system | |||
| Hydraulic station capacity | L | 600 | |
| Work pressure | MPa | 11 | |
| Hydraulic medium | Hydraulic oil | ||
| Cooling water system | |||
| Cooling water flow | T / h | 50 | |
| Water supply pressure | Mpa | 0.25-0.35 | |
| Inlet water temperature | °C | 5-35 | |
| Outlet temperature | °C | <55 | |