- 09
- Sep
500kg induction melting furnace
500kg induction melting furnace
1. the composition of 500kg induction melting furnace :
400kw intermediate frequency power supply – capacitor cabinet – aluminum shell or steel shell furnace – hydraulic tilting furnace system – remote control box ZXZ-40T closed loop cooling tower.
2.,the price of 500 kg induction melting furnace
The price of the 500kg induction melting furnace is calculated according to the power of the intermediate frequency power supply and the volume of the furnace body. Different configuration prices vary. This price is for reference only. For specific prices, please contact: firstfurnace@gmail.com
NO. | Item name | model | unit | Quantity | Price (RMB) |
1 | IF power cabinet | 400KW/0.5T/1000HZ | SET | 1 | 60000 |
2 | Filter compensation capacitor cabinet | 0.75- 2 000-1S | set | 1 | 20000 |
3 | 0.5T steel shell furnace | GW- 0.5T | set | 1 | 60000 |
4 | Water cooled cable | LHSD- 300 | set | 2 | 8000 |
5 | crucible | 0.5T furnace dedicated | only | 2 | 800 |
Total: ¥ 148800 |
3.the choice of 500kg induction melting furnace related configuration
Intermediate frequency power supply | Working form: parallel inverter structure or inverter series structure ( one power supply two furnace bodys ) |
Rectified form: 3- phase 6- pulse | |
Output power: 400kw | |
Power efficiency ≥98% | |
Start mode: buffer frequency conversion start | |
Startup rate: 100% (including heavy load) | |
Rated frequency: 500HZ – 1000HZ | |
AC voltage: 380v-660v | |
DC voltage: 500v-1000 | |
IF voltage: 750v-1500 V | |
DC current: 800 A | |
AC current: 650 A × 2 | |
Input frequency: 50Hz | |
Dimensions: 1400 mm × 90 0mm × 20 00 mm ( length × width ×height ) | |
Weight: 10 00 KG or so | |
Circulating water volume: ZXZ- 40 T | |
Furnace body | Rated capacity: 500 KG |
Maximum capacity: 60 0 KG | |
Power factor: ≥0.9 8 | |
Working mode: one electric two furnace | |
Melting time : about 45 minutes / furnace ( 1550 degrees cast iron) | |
Working temperature: 1550 °C | |
Maximum angle of the tilting furnace: 95° | |
Yoke: Oriented 0.23 water yoke | |
Outlet mode: side outlet | |
Circulating water volume: ZXZ- 40 T | |
Tilting method: hydraulic | |
Unit power consumption: ≤ 620 degrees / ton ± 5% 1550 ° C | |
Operating voltage: 1500 V | |
Dimensions: 1500 × 1600 × 100 0 | |
Weight: about 35 00KG | |
transformer | Rated capacity: 400 KVA |
Primary voltage: 10KV | |
Secondary voltage: 400 V / 6 phase rectification series | |
One phase: 3 phase | |
Secondary phase number: 3 phase 6 veins | |
Output form: three △ three Y |