3 T induction melting furnace technical parameter selection table
3 T induction melting furnace technical parameter selection table
| project | unit | 3t melting furnace data | Remark |
| Electric furnace parameters | |||
| Rated Capacity | t | 3.0 | |
| Maximum capacity | t | 3.3 | |
| Lining thickness | mm | 120 | |
| Induction coil inner diameter φ | mm | 980 | Sensor wall thickness 4mm |
| Induction coil height | mm | 1230 | |
| Maximum working temperature | °C | 1750 | |
| Electrical parameters | |||
| Transformer capacity | KVA | 2500 | |
| Transformer primary voltage | KV | 10 | |
| Transformer secondary voltage | V | 660 | |
| Rated power of intermediate frequency power supply | KW | 2000 | |
| IF power supply output voltage | V | 1300 | |
| Coil voltage | V | 2600 | |
| Rated working frequency | Hz | 500 | |
| Power conversion efficiency | % | 96 | |
| Startup success rate | % | 100 | |
| Comprehensive parameters | |||
| Melting rate ( heating up to 1600 ℃ ) | t/h | ≥ 3.0 | |
| Melting power consumption ( heating up to 1650 ℃ ) | KW • h/t | 610-640 | |
| Working noise | db | ≤ 75 | |
| Hydraulic system | |||
| Hydraulic station capacity | L | 350 | Double pumps |
| Work pressure | MPa | 11 | |
| Hydraulic medium | Hydraulic oil | ||
| Cooling water system | |||
| Cooling water flow | M3/h | 60 | |
| Inlet water temperature | °C | 5-35 | |
| Outlet temperature | °C | 35-55 | |
| Cooling water pressure | MPa | 0.2-0.35 | |