Napa tungku peleburan induksi duwe kegagalan trip?
Napa tungku peleburan induksi duwe kegagalan trip?
Nalika induction melting furnace is turned on, it will automatically trip. That is, when the induction melting furnace is turned on, when the intermediate frequency start switch is turned on, the main circuit switch will perform a protective trip or overcurrent protection.
Analisis Alasan Gagal:
Nalika sirkuit regulator saiki gagal, utamane nalika trafo saiki rusak utawa garis sambungan rusak, tungku peleburan induksi diwiwiti tanpa dipateni umpan balik saiki, saengga voltase DC langsung tekan nilai paling dhuwur, lan arus DC bakal langsung tekan nilai maksimum. , Nimbulake pawon listrik kanggo ngaktifake pangayoman liwat-saiki utawa nggawe ngalih sirkuit utama protèktif trip. Kajaba iku, bisa uga tombol pangaturan daya saka tungku leleh induksi diselehake ing titik paling dhuwur. Saliyane beban quenching, peralatan mbukak liyane kudu diselehake ing posisi minimal nalika miwiti, yen ora ing posisi minimal, iku bakal nimbulaké pangayoman overcurrent utawa nggawe saklar sirkuit utama protèktif amarga impact saiki gedhe banget Saka tripping.
Cara kanggo ngatasi masalah:
Priksa manawa trafo saiki wis rusak; apa ana sirkuit mbukak ing kabel antarane trafo saiki lan papan sirkuit; apa ana karusakan utawa mbukak sirkuit ing bagean regulator saiki.