Nima uchun induksion eritish pechining ishlamay qolishi bor?
Nima uchun induksion eritish pechining ishlamay qolishi bor?
qachon induktsiya eritish pechkasi is turned on, it will automatically trip. That is, when the induction melting furnace is turned on, when the intermediate frequency start switch is turned on, the main circuit switch will perform a protective trip or overcurrent protection.
Muvaffaqiyatsizlik sabablarini tahlil qilish:
Oqim regulyatorining sxemasi ishlamay qolganda, ayniqsa oqim transformatori shikastlanganda yoki ulanish liniyasi buzilganda, induksion eritish pechi tokni qayta tiklashni bostirmasdan ishga tushadi, shunda doimiy kuchlanish to’g’ridan-to’g’ri eng yuqori qiymatga etadi va doimiy oqim bo’ladi. to’g’ridan-to’g’ri maksimal qiymatga erishing. , Elektr pechining haddan tashqari oqimdan himoya qilishni faollashtirishi yoki asosiy kontaktlarning zanglashiga olib keladigan kalitini himoya qilish uchun o’chirib qo’ying. Bunga qo’shimcha ravishda, induksion eritish pechining quvvatni sozlash tugmasi eng yuqori nuqtada joylashgan bo’lishi mumkin. Yukni o’chirishga qo’shimcha ravishda, boshqa yuklash uskunalari ishga tushirilganda minimal holatda joylashtirilishi kerak, agar u minimal holatda bo’lmasa, bu haddan tashqari oqimdan himoyalanishni keltirib chiqaradi yoki o’chirishning haddan tashqari oqim ta’siridan asosiy kontaktlarning zanglashiga olib keladigan kalitini himoya qiladi.
Muammoni hal qilish usullari:
Oqim transformatorining shikastlanganligini tekshiring; oqim transformatori va elektron plata o’rtasidagi simlarda ochiq tutashuv bormi; oqim regulyatori qismida biron bir shikastlanish yoki ochiq tutashuv mavjudligi.