site logo

the unit power consumption of an induction melting furnace ?

the unit power consumption of an induction melting furnace ?

유도 용해로 refers to the total electric energy and metal consumption of the induction melting furnace in the process of heating, melting and (or) heating the scrap metal charge from room temperature to its rated temperature in a unit time (1 hour). The ratio of charge weight in kilowatt-hours per ton (kWh/t).

1. The induction melting furnace includes electric furnace melting equipment and its auxiliary equipment. The auxiliary equipment for casting and melting of the induction melting furnace includes its own supporting hydraulic and electrical transmission system for furnace body tilting, furnace cover opening and closing, water cooling system, control and measurement system, etc. The determination of its unit power consumption should be consistent with the induction melting furnace . The measurement of the unit power consumption of the main circuit of the furnace is carried out at the same time. Therefore, the total power consumption of the induction melting furnace also includes the sum of the unit power consumption of the main circuit of the induction melting furnace and the unit power consumption of the auxiliary equipment.

2. The unit power consumption measurement of the induction melting furnace shall comply with the national standards of GB/T 10067.3-2015 and GB/T 10066.3-2014.

3. 때 유도 용해로 is casting and smelting, the unit power consumption of different smelting temperatures is as follows:

 

Induction melting furnace variety specification code 유도 용해로

정격 용량 t

induction melting furnace , N, kW h/t
Cast iron 1450℃ Steel 1600℃
일등 이급 병종 일등 이급 병종
GW1 1 N ≤540 540<N ≤590 590<N ≤650 N≤600 600<N ≤660 660<N ≤720
GW1.5 1.5 N≤535 535<N ≤585 585<N ≤645 N ≤595 595<N ≤655 655<N ≤715
GW2 2 N ≤530 530<N ≤580 580<N ≤640 N ≤590 590<N ≤650 650<N ≤700
GW3 3 N≤525 525<N ≤575 575<N ≤635 N ≤585 585<N ≤645 645<N ≤695
GW5 5 N ≤520 520<N ≤570 570<N ≤630 N ≤580 580<N ≤640 640<N ≤690
GW10 10 N≤510 510<N ≤560 560<N ≤620 N≤570 570<N ≤630 630<N ≤680
GW20 20 / / / N≤605 605<N ≤650 650<N ≤705
GW40* 40 / / / N ≤585 585<N ≤630 630<N ≤685
GW60* 60 / / / N≤575 575<N ≤620 620<N ≤675
Remarks: With * means including the power loss of the induction melting furnace transformer (that is, the cumulative power consumption of the main circuit input is measured at the primary side of the transformer), without * means not including the power loss of the induction melting furnace transformer (that is, the accumulated power consumption of the main circuit input is at transformer secondary side metering).