site logo

Vakuumli atmosfera pechida o’choq haroratini avtomatik boshqarishni joriy etish

O’choq haroratini avtomatik boshqarishni joriy etish Vakuumli atmosfera pechkasi

Vacuum atmosphere furnace furnace temperature automatic control commonly used regulating laws include two-position, three-position, share, share integral and share integral differential. Resistance furnace temperature control is such a reaction conditioning process. Compare the actual furnace temperature and the atmosphere furnace temperature to obtain the error. After the error is processed, the control signal is obtained to adjust the thermal power of the resistance furnace, and then the furnace temperature control is completed.

1. Nazorat effekti (PID nazorati) jarayonni boshqarishda keng qo’llaniladigan boshqaruv shakli bo’lgan xato ulushi, integral va lotin bo’yicha ishlab chiqariladi.

2, two-position conditioning–it only has two states: on and off. When the furnace temperature of the vacuum atmosphere furnace is lower than the set value, the actuator is fully open; when the furnace temperature is higher than the set value, the actuator is fully closed. The actuator is usually a contactor.

3. Uch pozitsiyali konditsioner – bu yuqori va pastki chegaralarning ikkita berilgan qiymatiga ega. Vakuumli atmosfera pechining o’choq harorati pastki chegaraning berilgan qiymatidan past bo’lsa, kontaktor to’liq ochiladi; o’choq harorati yuqori chegaraning berilgan qiymati va pastki chegarasi o’rtasida bo’lsa, u bajariladi Aktuatorning bir qismi ochiq; atmosfera pechining o’choq harorati yuqori chegara o’rnatilgan qiymatdan oshib ketganda, aktuator to’liq yopiladi. Misol uchun, quvurli isitgich isitish elementi bo’lsa, isitish va issiqlikni saqlash quvvatidagi farqni to’ldirish uchun uch pozitsiyali konditsionerdan foydalanish mumkin.

Bundan tashqari, vakuumli atmosfera pechini sotib olayotganda, avvalambor, uning kuchini aniqlash kerak. Shu bilan birga, siz uning elektr isitish samaradorligini va quvvat omilini hisobga olishingiz kerak. Quvvatni aniqlashning ikki yo’li mavjud.

Ulardan biri issiqlik balansi usuli. Energiyani saqlash qonuniga ko’ra, vakuumli atmosfera o’chog’i tomonidan iste’mol qilinadigan umumiy issiqlik elektr isitish elementi chiqaradigan umumiy issiqlikka teng. Iste’mol qilinadigan umumiy issiqlik metallni isitishning samarali issiqligini va atmosfera pechining issiqlik yo’qotilishini o’z ichiga oladi. Issiqlik umumiy quvvatga aylantiriladi va elektr isitish samaradorligi hisobga olinadi, keyin esa quvvat zahirasi koeffitsienti bilan ko’paytiriladi. Ushbu koeffitsient pechning mahsuldorligi oshishi va issiqlik yo’qotilishi oshishi mumkinligini taxmin qiladi. Quvvat zahirasi koeffitsienti doimiy ishlaydigan atmosfera pechlari va intervalgacha ishlaydigan atmosferalar uchun. Boshqa turdagi o’choq – empirik usul bo’lib, u asosan o’choq hajmiga ko’ra o’choq quvvatini aniqlaydi.