site logo

Eksperimental yuqori haroratli elektr pechlari uchun umumiy nosozliklarni bartaraf etish usullari

Eksperimental muammolarni bartaraf etishning umumiy usullari yuqori haroratli elektr pechlari

1. Ishga tushganda displey yo’q va quvvat indikatori yonmaydi: elektr uzatish liniyasining buzilmaganligini tekshiring; asbobning orqa tarafidagi oqish va o’chirgichni ushlab turuvchi kalit “yoqilgan” holatidami; sug’urta yonishi mumkinmi.

2 .Continuous alarm at power-on: Press the “Start-in” button in the initial state. If the temperature is greater than 1000°C, the thermocouple is disconnected. Check whether the thermocouple is intact and whether the wiring is in good contact.

3. Eksperimental testga kirgandan so’ng, paneldagi “isitish” indikatori yonadi, lekin harorat ko’tarilmaydi: qattiq holat rölesini tekshiring.

4. Asbobning quvvatini yoqqandan so’ng, isitish indikatori eksperimental bo’lmagan holatda o’chirilgan bo’lsa, vaqti-vaqti bilan o’choq harorati ko’tariladi: o’choq simining har ikki uchida kuchlanishni o’lchang. Agar 220V AC kuchlanish mavjud bo’lsa, qattiq holat rölesi shikastlangan. Xuddi shu modelga o’zgartiring.