site logo

Precautions for operation of high temperature muffle furnace

Prekosyon pou operasyon an gwo tanperati mòf founo

1. The workpiece into the box-type high-temperature muffle furnace should not exceed the greater load capacity of the furnace floor. When loading and unloading the workpiece, ensure that the power supply is disconnected.

2. Retire fichye fè yo nan gwo founo dife a epi netwaye anba a nan gwo founo dife a pou anpeche fichye fè yo tonbe sou fil rezistans ak lakòz domaj kout sikwi.

3. Determine the reasonable process range according to the drawing requirements of the workpiece. Raise the temperature on time to ensure the operation of the furnace. Check the temperature of the instrument and calibrate it frequently to prevent the misoperation of the box-type high-temperature muffle furnace.

4. Wang Yi checked the installation position of the thermocouple. After the thermocouple is inserted into the furnace, it should be ensured that it does not touch the workpiece.

5. Yo ta dwe mete likid refwadisman an nan yon kote ki pratik tou pre pou diminye refwadisman pyès la apre li soti nan gwo fou a.

6. In order to ensure the furnace temperature, the box-type high-temperature muffle furnace door cannot be opened casually, and the situation in the furnace should be observed from the furnace door hole.

7. After the box-type high-temperature muffle furnace is overhauled, it must be baked in accordance with the regulations, and check whether the furnace hall and top insulation powder are filled, and whether the grounding is fastened to the furnace shell.

8. The working position should be correct when out of the furnace, and the clamping should be firm to prevent the hot workpiece from harming the human body.