1. The workpiece into the box-type high-temperature muffle furnace should not exceed the greater load capacity of the furnace floor. When loading and unloading the workpiece, ensure that the power supply is disconnected.

2. 철가루가 저항선에 떨어져 단락 손상을 일으키는 것을 방지하기 위해 로에서 철가루를 제거하고 로 바닥을 청소합니다.

3. Determine the reasonable process range according to the drawing requirements of the workpiece. Raise the temperature on time to ensure the operation of the furnace. Check the temperature of the instrument and calibrate it frequently to prevent the misoperation of the box-type high-temperature muffle furnace.

4. Wang Yi checked the installation position of the thermocouple. After the thermocouple is inserted into the furnace, it should be ensured that it does not touch the workpiece.

5. 용광로에서 나온 후 공작물의 냉각을 줄이기 위해 냉각수를 가까운 편리한 위치에 배치해야 합니다.

6. In order to ensure the furnace temperature, the box-type high-temperature muffle furnace door cannot be opened casually, and the situation in the furnace should be observed from the furnace door hole.

7. After the box-type high-temperature muffle furnace is overhauled, it must be baked in accordance with the regulations, and check whether the furnace hall and top insulation powder are filled, and whether the grounding is fastened to the furnace shell.

8. The working position should be correct when out of the furnace, and the clamping should be firm to prevent the hot workpiece from harming the human body.