Emergency treatment method for water shutdown of induction melting furnace water system

Emergency treatment method for water shutdown of induction melting furnace water system

A. Forno fusorio a induzione il sistema idrico si spegne

Il primo passo è avviare il generatore, se l’avvio fallisce, viene aperta l’acqua di emergenza

The second step is to check the water pressure of the emergency pump. Close the valves at the inlet and outlet of the furnace body.

The third step is to check the furnace body return water pipe, the water temperature is too high, the return water temperature, open the furnace body emergency, check the emergency water, the water outlet, Check whether there is water flowing out of the water inlet and outlet valves, check the furnace body’s return pipe and the temperature of the return water.

B. Precauzioni dopo l’avvio di emergenza dell’acqua del forno fusorio a induzione

1. La prima volta per osservare se c’è acqua che esce dall’uscita dell’acqua di emergenza. Se non c’è acqua che esce dall’uscita dell’acqua, significa che il tubo di circolazione dell’acqua

Non c’è rifornimento d’acqua di emergenza sulla strada o la valvola sulla relativa condotta non è aperta. È necessario scoprire immediatamente il motivo e reintegrare l’acqua di emergenza in tempo.

entrare

2. Nello stato di funzionamento dell’acqua di emergenza, il personale in loco deve rilevare in ogni momento la temperatura della tubazione dell’acqua di ritorno di ciascun corpo del forno. Se viene trovata la temperatura di ciascuna tubazione

Quando continua a salire e non c’è tendenza al raffreddamento, il ferro fuso nel forno deve essere versato in tempo.