site logo

Mbinu ya matibabu ya dharura kwa kuzimwa kwa maji ya mfumo wa maji ya kuyeyuka kwa tanuru

Mbinu ya matibabu ya dharura kwa kuzimwa kwa maji ya mfumo wa maji ya kuyeyuka kwa tanuru

A. Induction tanuru ya kuyeyuka mfumo wa maji huzima

Hatua ya kwanza ni kuanza jenereta, ikiwa mwanzo unashindwa, basi maji ya dharura yanageuka

Hatua ya pili ni kuangalia shinikizo la maji la pampu ya dharura. Funga valves kwenye mlango na mlango wa mwili wa tanuru.

The third step is to check the furnace body return water pipe, the water temperature is too high, the return water temperature, open the furnace body emergency, check the emergency water, the water outlet, Check whether there is water flowing out of the water inlet and outlet valves, check the furnace body’s return pipe and the temperature of the return water.

B. Tahadhari baada ya maji ya dharura kuanza kwa tanuru ya kuyeyusha induction

1. The first time to observe whether there is water flowing out of the emergency water outlet. If there is no water flowing out of the water outlet, it means the water circulation pipe

Hakuna ujazo wa dharura wa maji kwenye barabara au vali kwenye bomba husika haijafunguliwa. Inahitajika kujua sababu mara moja na kujaza maji ya dharura kwa wakati.

kuingia

2. In the emergency water working state, the on-site personnel need to detect the temperature of each furnace body’s return water pipeline at all times. If the temperature of each pipeline is found

Wakati inaendelea kuongezeka na hakuna mwenendo wa baridi, chuma kilichoyeyuka kwenye tanuru kinapaswa kumwagika kwa wakati.