- 18
- May
Hva skal jeg gjøre med overstrømsbeskyttelsen når induksjonssmelteovnen har full effekt?
What should I do with the overcurrent protection when the induksjon smelteovnen er på full effekt?
1. Fenomenet feil
Omformeren svikter når mellomfrekvenseffekten gis ut med full effekt, og overstrømsbeskyttelsen er aktivert. Ved lav effekt synker plutselig mellomfrekvensen, Ua synker og Id øker.
2. Failure analysis and treatment
According to the fault phenomenon, it is preliminarily judged that one bridge arm of the inverter bridge is not conductive. If the No. 3 bridge arm is not conductive, the No. 4 bridge arm cannot be turned off.
Observing U4 with an oscilloscope is also a straight line. The voltage of the No. 3 bridge arm is equal to the load voltage, so the U3 waveform is a complete sine wave. When the above-mentioned fault occurs, first determine whether the thyristor is not conducting or the other part of the bridge arm is open.
Hvis tyristoren ikke er ledende, kan oscilloskopet brukes til ytterligere å bestemme om triggerkretsen er defekt, tyristorens kontrollpol er defekt eller linjen er defekt.
Bruk først et oscilloskop for å sjekke om det er en triggerpuls på broarmen og om triggerpulsen er normal. Hvis triggerpulsen ikke er normal, ligger feilen i triggerkretsen. Bryteren bør settes til inspeksjonsposisjonen, og bølgeformene til hver del av utløserkretsen bør kontrolleres trinnvis for å finne feilen. punkt. Hvis triggerpulsen er normal, bruk et multimeter for å sjekke om kontrollpolen til tyristoren er åpen eller kort.
If it is normal, check the resistance between the control electrode and the cathode of the thyristor. If the internal resistance of the control pole is too large, replace the thyristor.
If the thyristor is constantly off, check whether the group of thyristors that are off is short-circuited. If it is normal, check whether the turn-off time of the thyristor is too long.