- 18
- Mar
What is the cause of the low temperature of the muffle furnace
What is the cause of the low temperature of the iziko lomlilo
Kufuneka enze ntoni umsebenzisi wesithando somlilo xa iqondo lobushushu lombane lisezantsi? Siyintoni isizathu soku? Ngaba sikho isicombululo sale ngxaki? Kolu luhlu lweengxaki, umhleli we-Huarong uyakuxelela, le Le meko kulula ukuyisombulula.
Makhe siqale sihlalutye isizathu sobushushu obuphantsi besithando somlilo:
1. Ubushushu be-terminal ye-reference ye-thermocouple ingaba phezulu kakhulu.
2. Ukuvuza okanye ukuwohloka kwe-electrode ye-thermocouple.
3. Indawo yokulinganisa i-thermocouple ikude kakhulu.
4. Intambo yembuyekezo kunye ne-thermocouple idibaniswe ngokuphambeneyo okanye ayihambelani, okanye i-insulation iyancitshiswa. Ngokusisiseko ezi zizathu zine.
Emva kokwazi izizathu, saqalisa ukwenza izicombululo ngesizathu ngasinye.
Isizathu 1: Jonga ubushushu besiphelo sereferensi ukwenza ukuba uhlangabezane neemfuno zobushushu.
Isizathu sesi-2: Khangela ucingo lokudibanisa lwe-electrode ye-thermocouple, ukuba kukho ukuvuza, kufuneka utshintshe ucingo lokudibanisa lwe-furnace ye-muffle. Ukuba i-electrode iyancipha, kufuneka itshintshwe nge-thermocouple entsha kunye efanayo.
Isizathu sesi-3: Lungisa indawo yokulinganisa i-thermocouple de iqondo lokushisa elilinganisiweyo lichanekile.
Reason 4. Compensation wire, if the muffle furnace wire is connected reversely, just correct it. If it is not matched or the insulation is reduced, then a new compensating wire must be replaced.
From the above, we can see that when the high-temperature muffle furnace fails, let’s not panic. First turn off the power supply of the electric furnace, and then analyze the cause of the failure. After finding the cause, we can seek the correct solution.