Vacuum box atmosphere furnace KSX3-10-10
Vacuum box atmosphere furnace KSX3-10-10
Performance characteristics of vacuum box atmosphere furnace
■Good sealing performance, can be used for vacuum atmosphere experiments;
■It can pass a variety of mixed gas for atmosphere protection;
■The control system adopts LTDE technology, with 30-band programmable function, and two-level over-temperature protection.
The vacuum box atmosphere furnace has good sealing performance and is suitable for atmosphere protection experiments and vacuum high temperature experiments. The furnace port is designed with a water cooling device, equipped with a double-head valved air inlet, protective cover, gas flow meter, silicone tube, single-head valved air outlet, protective cover, and vacuum pressure gauge. When using, it is necessary to connect the cold liquid in the low temperature tank provided by the user to the cooling device (water cooling method can also be used when the temperature is not high). In the atmosphere protection experiment, the air can be drawn into the degrading gas, so that the high-temperature heating workpiece will not produce oxidative decarburization, and it is used for high-temperature sintering with gas protection. It can also be used in heat treatment processes such as general quenching. When the furnace is in use, it is necessary to extract the vacuum in the furnace or fill it with degrading gas and turn on the water-cooling device to increase the temperature.
Operation instructions reference:
The vacuum box atmosphere furnace has the characteristics of good airtightness. Equipped with a vacuum pressure gauge, double-head valve inlet pipe, single-head valve outlet pipe, safety cover, silicone tube. It can be used for high-temperature atmosphere protection experiments with higher purity concentrations. The furnace mouth is equipped with a cooling device, which must be connected with refrigerant when in use. Special tips for operation:
(1) Equipped with a vacuum pump, each time the air in the furnace is drawn, it is advisable not to exceed four pointer scales. When the pointer of the vacuum gauge drops close to four points, the pumping stops and the degrading gas is filled to make the pointer return to 0. Or a little bit greater than 0, then pump air…inflate, (if it is filled with nitrogen, it must not be filled to prevent safety accidents caused by gas expansion);
(2) If there is no vacuum pump that needs nitrogen protection, connect the inlet pipe, fill with nitrogen, and slightly release the front outlet valve.
(3) After completing the above content, set the required temperature program on the operation panel;
(4) At the end of the experiment, it is necessary to ensure that the furnace temperature falls within a safe range below 100 degrees, and the furnace door can be opened after opening the gas valve.
Four. Precautions
A. The cooling device interface needs to be connected with coolant before heating up;
B. Suitable for heating in atmosphere protection or vacuum state;
C. It is strictly forbidden to heat up in a non-vacuum state or in an object with gas expansion without atmosphere protection
D The housing of the instrument must be grounded effectively to ensure safe use.
E The instrument should be placed in a well-ventilated room, and no flammable and explosive materials should be placed around it.
F This instrument has no explosion-proof device, and no flammable and explosive materials can be put into it.
G Turn off the instrument fifteen minutes after the instrument finishes work (to facilitate the heat dissipation of the instrument)
H. After the furnace is used, you must wait until the furnace temperature drops to at least 100 degrees, open the valve and release the gas before opening the furnace door, otherwise there will be safety hazards and even personal injury.
Note: The furnace block at the door must be blocked before the door can be closed and the temperature can be raised.
Equipped with technical information and accessories
Operating Instructions
warranty card
Double-headed air inlet valve, single-headed air outlet valve
Main components
LTDE programmable control instrument
solid state relay
Intermediate relay
Thermocouple
Cooling motor
High temperature heating wire
Optional accessories:
Barometer
After-sales service:
Responsible for remote technical guidance to users
Provide equipment spare parts and accessories in time
Provide technical consultation and support during equipment use
Respond immediately within 8 working hours after receiving customer failure notification
product name | Vacuum box atmosphere furnace KSX3-10-10 |
Furnace shell material | Premium cold plate |
Furnace material | Ultra lightweight fiberboard |
Heating element | high temperature resistance wire |
Insulation method | Thermal insulation brick and thermal insulation cotton |
Temperature measuring element | S index platinum rhodium–platinum thermocouple |
temperature range | 100 ~ 1000℃ |
Volatility | ±1℃ |
Display accuracy | 1℃ |
Furnace size | 500*500*500 MM |
Dimensions | 约 MM |
Heating rate | ≤50℃/min |
Total power | 7.5KW |
power supply | 380V, 50Hz |
Total Weight | About kg |