- 22
- Feb
Завсрын давтамжийн трансформаторын дизайны функц ба үр ашиг
Завсрын давтамжийн трансформаторын дизайны функц ба үр ашиг
1) It has a cylindrical primary winding and a fixed transformation ratio of the outer core-shaped permeable magnet (shell type) structure. Its primary winding has a fixed number of turns, which is suitable for fixed products of special hardening machines, such as those equipped with split-and-close inductors. Crankshaft quenching machine tools, camshafts, auto flywheel ring gears and other special machine tools. Its advantages are simple structure and convenient maintenance.
2) With a multi-turn ratio outer core-shaped magnetic conductor structure with a disc-shaped primary winding, its transformation ratio can be adjusted by changing the tap plate, and its primary winding turns range is 10 to 34 turns. The secondary winding is connected to 2 turns or 1 turn through the inductor connection board. Its main advantage is that it can be adapted to the requirements of different sensor parameters through adjustment.
3) Нимгэн завсрын давтамжийн трансформатор нь голчлон тахир голыг унтраах машин хэрэгсэлд зориулагдсан. Энэ нь зөвхөн 62 мм-ийн нимгэн өргөн, зузаантайгаараа онцлог бөгөөд энэ нь үндсэн журнал болон холбогч бариулын хошуу хоорондын зайд ойрхон байдаг тул олон трансформаторыг суурилуулах шаардлагад дасан зохицож чаддаг.
(3) Феррит цөмт унтраах трансформатор нь соронзон цөмд феррит ашигладаг бөгөөд энэ нь ерөнхийдөө усаар хөргөдөггүй, жижиг хэмжээтэй, хөнгөн жинтэй байдаг.
For the configuration of the intermediate frequency transformer, the capacity selection is generally considered as 3~5 times the capacity of the intermediate frequency power supply. In fact, the transformer also has a utilization factor, that is, its load factor. When the load rate is low, the capacity can be smaller, and when the load rate is high, the capacity must be larger. Another point is that when a transformer has different transformation ratios, its copper loss is also different. Figure 2-15 shows the relationship between the specific load and loss of the two transformers and the secondary voltage U2. It can be seen from the graph curve that when the secondary voltage is 30~40V, the transformer loss is the smallest.
- Завсрын давтамжийн трансформатор ба ороомгийн холболт Завсрын давтамжийн трансформаторыг өндөр эсэргүүцэлтэй ороомгийн хувьд ихэвчлэн 2 эргэлт эсвэл хоёрдогч ороомгийн 3 эргэлт, илүү өндөр эсэргүүцэл нь завсрын давтамжийн цахилгаан тэжээлд шууд холбогдохын тулд завсрын давтамжийн автотрансформатор эсвэл ороомгийг ашигладаг. Ийм ороомог нь ихэвчлэн том диаметртэй олон эргэлттэй индукторууд байдаг.