- 06
- Sep
2T induction melting furnace technical configuration selection table
2T induction melting furnace technical configuration selection table
1. 2T induction melting furnace power supply parameter selection table
Serial number | project | unit | parameter | Remark |
1 | Transformer capacity | KVA | 1500 | 10KV/2*660V / 6phase /50H△/ Ddoyn-11(ONAN) |
2 | Transformer primary voltage | KV | 10 | |
3 | Transformer secondary voltage | V | 660 | |
4 | rated power | KW | 1250 | power supply |
5 | Rated frequency | KHz | 0.5 | |
6 | DC voltage | V | 830 | |
7 | IF voltage | V | 1200 | |
8 | Induction coil port voltage | V | 2400 | |
11 | Rectifier | 12 pulses | ||
12 | Inverter | 8 thyristors | ||
13 | Power conversion efficiency | > 0.95 | ||
14 | Power factor | > 0.92 | Under rated power | |
15 | Constant power output time | > 92% | During the melting cycle | |
16 | Startup success rate | 100% | ||
17 | Working noise | dB | ≤85 | 1 meter away |
2. 2T induction melting furnace
Serial number | project | Unit | Parameter |
1 | Rated Capacity | t | 2.0 |
2 | Rated working temperature | C | 1600 |
3. The melting rate and melting power consumption of 2T induction melting furnace ,
Serial number | project | Unit | Parameter |
1 | Melting rate (1600 C) | t/h | 2.0 |
2 | Melting power consumption (1600 C) | kwh/t | ≤610 |
. 4, 2T induction melting furnace of the hydraulic system
Serial number | project | Unit | Parameter |
1 | Hydraulic station capacity | L | 500 |
2 | Work pressure | Mpa | 10 |
3 | input power | KW | 5.5 |
4 | Work flow | L/ min | >45 |
5 | The hydraulic oil supplier provides the model, and the buyer is responsible for the purchase and cost. |
5. Technical requirements for supporting facilities of 2T induction melting furnace and special transformers
Serial number | project | parameter |
1 | Rated Capacity | 1500KVA |
2 | Primary voltage | 10KV±5% 3 phase 50HZ |
3 | Secondary voltage | 660V*2 |
4 | Primary current | 86.6A |
5 | Secondary current | 656A*2 /(660V) |
6 | Connection group | Ddo-yn11 |
7 | Impedance voltage | UK=6% |
8 | cooling method | ONAN |
9 | Pressure regulation method | 3 gears no-excitation manual voltage regulation |
10 | Between network side and valve side | Add shielding to reduce the impact of harmonics on the network side |
11 | Safeguard | Heavy and light gas alarm, overpressure release and high oil temperature alarm |
12 | other | Low loss, high reliability, low noise, etc. |
13 | Winding | Copper core |
14 | Silicon steel sheet | WISCO produces a new oriented silicon steel sheet, model 30Q130. |