Installation method of vacuum atmosphere furnace
Installationsmetode af vakuum atmosfære ovn
Vacuum atmosphere furnaces are now used in many industrial manufacturing in the heating process. For the atmosphere furnace, we should first understand the structure of the atmosphere furnace before operating, in order to have a better operation of the atmosphere furnace, and to deal with various conditions in time during operation. .
The structure of the atmosphere furnace is mainly composed of a furnace frame, a furnace shell, a furnace lining, a furnace door device, an electric heating element and an auxiliary device. The function of the furnace frame is to bear the load of the furnace lining and the workpiece, and usually there are section steel welded into a frame, and the steel plate is covered. The function of the furnace shell of the vacuum atmosphere furnace is to protect the furnace lining, strengthen the structure of the electric furnace and maintain the airtightness of the electric furnace. The steel plate is usually welded on the steel frame. The reasonable design of the furnace frame and the furnace shell has sufficient strength. Let’s take a look at the installation method:
1. Vakuum-atmosfæreovnen behøver ikke speciel installation, den skal kun placeres på en flad jord eller arbejdsbord. Controlleren bør undgå vibrationer, og placeringen bør ikke være for tæt på den elektriske ovn for at forhindre overophedning, og de elektroniske komponenter kan ikke fungere normalt.
2. Before installing the electric furnace, check whether it is damaged or incomplete due to transportation or other reasons. If it is complete, remove the dirt from the parts first, repair the defects found, and then install it.
3. Indfør termoelementet gennem parhullet, og fyld mellemrummet mellem parhullet og termoelementet med asbestreb for at forhindre varmetab.
4. Kontroller, om det elektriske varmeelement i vakuumatmosfæreovnen er knækket, revnet, kraftigt bøjet og falder ud af murstenene.
5. Se venligst ledningsdiagrammet i controllermanualen for at tilslutte netledningen, den elektriske ovnledning og kompensationsledningen.
6. After the wire is connected, please follow the procedure below to bake the new vacuum atmosphere furnace before using it for the first time.