site logo

Sida loo isticmaalo multimeter si loo hubiyo tayada iyo polarity ee thyristor?

Polarity iyo tayada SCR waxaa lagu xukumi karaa multimeter tilmaame ama multimeter dhijitaal ah. Yunnan Changhui Instrument Manufacturing Co., Ltd. ayaa si gooni ah u soo bandhigtay adeegsiga labadan multimeter -ka habka loo cabbirayo dabacsanaanta iyo tayada SCR.

  1. Isticmaal multimeter tilmaame si aad u hubiso kala -duwanaanshaha iyo tayada SCR

Marka loo eego mabda’a isgoyska PN, iska caabbinta u dhexeysa saddexda tiir ee thyristor waxaa lagu cabbiri karaa block -ka ohmic “R × 10” ama “R × 100” si loo xukumo inay wanaagsan tahay iyo inay xun tahay. Waxaa jira isgoyska PN oo u dhexeeya korantada koontaroolka G iyo cathode K ee thyristor. Xaaladaha caadiga ah, iska caabinteeda hore waxay u dhaxaysaa tobanaan ohms ilaa boqolaal ohms, iyo iska caabinta dambe guud ahaan way ka weyn tahay iska caabin hore. Mararka qaarkood cabbirka iska -caabbinta iska -caabbinta ee cirifka koontaroolku waa yar yahay, taas oo aan macnaheedu ahayn in cirifka koontaroolku leeyahay sifooyin liita. Waxay badanaa kuxirantahay inay buuxiso astaamaha isgoyska PN.

  1. Isticmaal multimeter -ka dhijitaalka ah si aad u hubiso polarity iyo tayada SCR

Ku xakumi multimeter -ka dhijitaalka ee korontada ee thyristor -ka baloogga diode -ga, ku xiro hogaanka imtixaanka gaduudka hal koronto, iyo hogaaminta tijaabada madow si aad ula xiriirto labada koronto ee kale. Haddii mid ka mid ahi muujiyo in danabku yahay toban meelood oo ka mid ah danab, markaa hoggaanka tijaabada gaduudan wuxuu ku xiran yahay koontaroolka korontada G, hogaanka tijaabada madow wuxuu ku xiran yahay cathode K, inta kalena waa anode A. Haddii wuxuu muujinayaa buux -dhaaf labada jeerba, waxay ka dhigan tahay in hogaanka tijaabada cas uusan ku xirnayn koontaroolka koontaroolka, oo korontadu waxay u baahan tahay in la beddelo oo dib loo baaro.

Si loo tijaabiyo kartida kicinta ee thyristor -ka, multimeter -ka dhijitaalka ah ayaa lagu hagaajiyay baloogga PNP. Wakhtigan, labada dalool ee E ee ku yaal godka hFE si togan ayaa loo soo dallacaa, daloolka C -na si taban ayaa loo qaadaa, danabkuna waa 2.8V. Saddexda koronto ee thyristor -ka waxaa soo saaray silig, anode A iyo cathode K lead ayaa la galiyay godadka E iyo C siday u kala horreeyaan, korantada koontaroolka G -na waa la hakiyay. Waqtigan xaadirka ah, thyristor -ka waa la damiyaa, hadda anode waa eber, 000na waa la soo bandhigi doonaa.

Geli tiirka koontaroolka G godka E ee kale. Qiimaha la soo bandhigay ayaa si xawli ah u kordhaya laga bilaabo 000 ilaa calaamadda buux dhaafka ah la soo bandhigo, ka dibna isla markiiba loo beddelo 000, ka dibna laga beddelo 000 si mar kale loo badiyo, iwm. Habkan waxaa loo isticmaali karaa in lagu go’aamiyo in kicinta thyristor -ku ay tahay mid la isku halleyn karo. Si kastaba ha ahaatee, wakhtiga imtixaanka waa in la soo gaabiyo intii suurtogal ah iyada oo ay ugu wacan tahay imminka baaxadda weyn ee imtixaankan oo kale. Haddii loo baahdo, iska caabin ilaalin oo dhowr boqol oo ohm ah ayaa si taxane ah loogu xiri karaa anode SCR.

Haddii xannibaadda NPN la isticmaalo, anode A ee thyristor -ka waa in lagu xiraa daloolka C, iyo cathode K ilaa godka E si loo hubiyo in danab hore loo adeegsaday uu yahay. Markaad hubinayso awoodda kicinaysa, ha gelin korontada koontaroolka godka B, sababtoo ah danabyada daloolka B waa hooseeyaa, SCR -na lama shidi karo.