site logo

Intermediate frequency induction heating furnace for automobile axle housing

Intermediate frequency induction heating furnace for automobile axle housing

06050035 A, the workpiece parameters and process requirements of the intermediate frequency induction heating furnace for the axle housing

name Specifications and requirements Remark
Heating material 16 manganese steel, Q4200B, etc.  
heating method Overall diathermy  
Final heating temperature 900-920 ℃± 20 ℃  
Largest blank Length 1640mm Width 520 mm Thickness 16 mm ( 14 mm )  
Single blank weight ( MAX ) 60Kg  
Blank width range 268~415mm  
Production program 160,000 pieces / year 136 seconds / piece per unit Two consecutive shifts
Power 750kW Single

B. The composition of the intermediate frequency induction heating furnace for the axle housing is shown in the following table

content quantity Remark
 

Intermediate frequency heating part

low voltage switch box 2 sets Assemble each and each intermediate frequency power supply cabinet together
Intermediate frequency power supply KGP S 75 0 /6.0 K Hz 2 sets  
Compensation capacitor cabinet 2 sets The induction heating furnace is installed on the compensation capacitor cabinet
Induction heating furnace GTR 40 2 sets Rectangular transverse feeding, opening height 40mm .
Connect copper bars or cables 2 sets The length depends on the site
 

 

 

 

Mechanical transmission part

Roller feeding mechanism 2 sets  
Electromagnetic suction device 2 sets  
Parallel moving trolley 2 sets  
Pneumatic pushing mechanism 2 sets  
Quick discharge mechanism 2 sets  
Two-way power conveying roller table 1 set  
Material limit device 2 sets  
Double rod pneumatic positioning device 1 set  
Feeding manipulator 1 set  
 

 

 

Control section

Infrared Thermometer 2 sets Installed at the sensor outlet
Temperature display instrument 2 sets Installed on the operation cabinet
PLC 2 sets Mitsubishi Q series (or 3 units)
Proximity switch Multiple  
Photoelectric switch 4 sets  
Outer console 1 set  
connecting cables 1 set The length depends on the site
Cooling part Pure water water – water cooler 2 sets FSS-350
2 cubic meters of water storage tank   spare
spare parts See the table below    
Installation materials According to the detailed design and site conditions 1 set