The buffer modulated wave aluminum melting furnace must be baked before use. For the buffer modulated wave aluminum melting furnace that has just been lined, it should be naturally dried in the air at not less than 10-15°C for 2 to 3 days before being energized.

The oven process is as follows (see crucible maintenance process for details):

A. The room temperature rises to 100°C, the heating current is 15A, the empty pot is heated to 100°C without a lid, and the temperature is constant for 2h;

B. Mundhakaken suhu saka 100 ℃ kanggo 200 ℃, panas saiki 20A, pot kosong digawe panas kanggo 200 ℃ tanpa tutup, lan suhu pancet kanggo 2h;

C. Mundhakaken 200 ℃ kanggo 300 ℃, dadi panas saiki 30A, ing crucible kosong digawe panas kanggo 300 ℃ tanpa tutup, suhu pancet kanggo 1h;

D. Mundhakake suhu saka 300 ° C nganti 800 ° C, panas ing beban lengkap, nutupi crucible kosong lan panas nganti 800 ° C, njaga suhu konstan kanggo 1h;

When the buffer modulated wave aluminum melting furnace is put aside for a long time and then used again, the furnace should also be baked in accordance with the above regulations.