Method of buffering modulating wave melting aluminum furnace

Method of buffering modulating wave melting aluminum furnace

The buffer modulated wave aluminum melting furnace must be baked before use. For the buffer modulated wave aluminum melting furnace that has just been lined, it should be naturally dried in the air at not less than 10-15°C for 2 to 3 days before being energized.

The oven process is as follows (see crucible maintenance process for details):

A. The room temperature rises to 100°C, the heating current is 15A, the empty pot is heated to 100°C without a lid, and the temperature is constant for 2h;

B. Phakamisa izinga lokushisa lisuka ku-100℃ liye ku-200℃, izinga lokushisa lingu-20A, ibhodwe elingenalutho lishiselwa ku-200℃ ngaphandle kwesivalo, futhi izinga lokushisa lihlala lihlala ku-2h;

C. Phakamisa i-200℃ kuya ku-300℃, ukushisa kwamanje i-30A, i-crucible engenalutho ishisa ku-300 ℃ ngaphandle kwesivalo, izinga lokushisa elihlala njalo le-1h;

D. Phakamisa izinga lokushisa kusuka ku-300 ° C kuya ku-800 ° C, ukushisa ngomthwalo ogcwele, vala i-crucible engenalutho bese ushisa kuze kufike ku-800 ° C, gcina izinga lokushisa lingaguquki i-1h;

When the buffer modulated wave aluminum melting furnace is put aside for a long time and then used again, the furnace should also be baked in accordance with the above regulations.