Method of buffering modulating wave melting aluminum furnace

Method of buffering modulating wave melting aluminum furnace

The buffer modulated wave aluminum melting furnace must be baked before use. For the buffer modulated wave aluminum melting furnace that has just been lined, it should be naturally dried in the air at not less than 10-15°C for 2 to 3 days before being energized.

The oven process is as follows (see crucible maintenance process for details):

A. The room temperature rises to 100°C, the heating current is 15A, the empty pot is heated to 100°C without a lid, and the temperature is constant for 2h;

B. Verhoog de temperatuur van 100 tot 200 ℃, de verwarmingsstroom is 20 A, de lege pot wordt zonder deksel verwarmd tot 200 ℃ en de temperatuur is constant gedurende 2 uur;

C. Verhoog 200℃ tot 300℃, verwarmingsstroom 30A, de lege smeltkroes wordt verwarmd tot 300℃ zonder deksel, constante temperatuur gedurende 1 uur;

D. Verhoog de temperatuur van 300°C tot 800°C, verwarm bij volle belasting, dek de lege kroes af en verwarm tot 800°C, houd de temperatuur gedurende 1 uur constant;

When the buffer modulated wave aluminum melting furnace is put aside for a long time and then used again, the furnace should also be baked in accordance with the above regulations.