site logo

Hoe om omskakelaar-tiristor vir induksie-smeltoond te kies?

How to choose inverter thyristor for induksie smeltoond?

1) Kies volgens die bedryfsfrekwensiereeks van die induksie-smeltoond;

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) Kies volgens die uitsetkrag van die induksie-smeltoond;

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

Die geselekteerde huidige 300A/1400V tiristor met krag tussen 50KW en 100KW. (380V-infasespanning)

Die geselekteerde huidige 500A/1400V tiristor met ‘n krag van 100KW-250KW. (380V-infasespanning)

Die geselekteerde huidige 800A/1600V tiristor met ‘n drywing wat wissel van 350KW tot 400KW. (380V-infasespanning)

Die geselekteerde huidige 1500A/1600V tiristor met krag tussen 500KW en 750KW. (380V-infasespanning)

Die geselekteerde huidige 1500A/2500V tiristor met krag tussen 800KW en 1000KW. (660V-infasespanning)

Die geselekteerde huidige 2000A/2500V tiristor met ‘n krag van 1200KW-1600KW. (660V-infasespanning)

Die geselekteerde huidige 2500A/3000V tiristor met krag tussen 1800KW en 2500KW. (1250V-infasespanning)