How to choose inverter thyristor for lò nấu chảy cảm ứng?
1) Lựa chọn theo dải tần hoạt động của lò nấu chảy cảm ứng;
The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.
The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.
The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.
KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.
The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.
2) Chọn theo công suất đầu ra của lò nấu chảy cảm ứng;
According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.
Dòng điện 300A / 1400V thyristor được chọn có công suất từ 50KW đến 100KW. (Điện áp pha 380V)
Dòng điện được chọn 500A / 1400V thyristor với công suất 100KW-250KW. (Điện áp pha 380V)
Thyristor 800A / 1600V được lựa chọn hiện tại có công suất từ 350KW đến 400KW. (Điện áp pha 380V)
Dòng điện 1500A / 1600V thyristor được chọn có công suất từ 500KW đến 750KW. (Điện áp pha 380V)
Dòng điện 1500A / 2500V thyristor được chọn có công suất từ 800KW đến 1000KW. (Điện áp pha 660V)
Dòng điện được chọn 2000A / 2500V thyristor với công suất 1200KW-1600KW. (Điện áp pha 660V)
Dòng điện 2500A / 3000V thyristor được chọn có công suất từ 1800KW đến 2500KW. (Điện áp pha 1250V)