site logo

Cách chọn thyristor biến tần cho lò nung cảm ứng?

How to choose inverter thyristor for lò nấu chảy cảm ứng?

1) Lựa chọn theo dải tần hoạt động của lò nấu chảy cảm ứng;

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) Chọn theo công suất đầu ra của lò nấu chảy cảm ứng;

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

Dòng điện 300A / 1400V thyristor được chọn có công suất từ ​​50KW đến 100KW. (Điện áp pha 380V)

Dòng điện được chọn 500A / 1400V thyristor với công suất 100KW-250KW. (Điện áp pha 380V)

Thyristor 800A / 1600V được lựa chọn hiện tại có công suất từ ​​350KW đến 400KW. (Điện áp pha 380V)

Dòng điện 1500A / 1600V thyristor được chọn có công suất từ ​​500KW đến 750KW. (Điện áp pha 380V)

Dòng điện 1500A / 2500V thyristor được chọn có công suất từ ​​800KW đến 1000KW. (Điện áp pha 660V)

Dòng điện được chọn 2000A / 2500V thyristor với công suất 1200KW-1600KW. (Điện áp pha 660V)

Dòng điện 2500A / 3000V thyristor được chọn có công suất từ ​​1800KW đến 2500KW. (Điện áp pha 1250V)