Bagaimana untuk memilih thyristor penyongsang untuk relau lebur aruhan?

How to choose inverter thyristor for relau lebur aruhan?

1) Pilih mengikut julat frekuensi operasi relau lebur aruhan;

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) Pilih mengikut kuasa keluaran relau lebur aruhan;

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

Thyristor 300A/1400V semasa yang dipilih dengan kuasa antara 50KW dan 100KW. (voltan fasa masuk 380V)

Thyristor 500A/1400V semasa yang dipilih dengan kuasa 100KW-250KW. (voltan fasa masuk 380V)

Thyristor 800A/1600V semasa yang dipilih dengan kuasa antara 350KW hingga 400KW. (voltan fasa masuk 380V)

Thyristor 1500A/1600V semasa yang dipilih dengan kuasa antara 500KW dan 750KW. (voltan fasa masuk 380V)

Thyristor 1500A/2500V semasa yang dipilih dengan kuasa antara 800KW dan 1000KW. (voltan fasa masuk 660V)

Thyristor 2000A/2500V semasa yang dipilih dengan kuasa 1200KW-1600KW. (voltan fasa masuk 660V)

Thyristor 2500A/3000V semasa yang dipilih dengan kuasa antara 1800KW dan 2500KW. (voltan fasa masuk 1250V)