site logo

Як выбраць інвертарны тырыстар для індукцыйнай плавільнай печы?

How to choose inverter thyristor for індукцыйная плавільная печ?

1) Выберыце ў адпаведнасці з дыяпазонам працоўных частот індукцыйнай плавільнай печы;

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) Выберыце ў адпаведнасці з выхадной магутнасцю індукцыйнай плавільнай печы;

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

Выбраны тырыстар 300A/1400V з магутнасцю ад 50кВт да 100кВт. (Напружанне фазы 380 В)

Выбраны тырыстар ток 500A/1400V з магутнасцю 100KW-250KW. (Напружанне фазы 380 В)

Выбраны ток тырыстар 800A/1600V з магутнасцю ад 350кВт да 400кВт. (Напружанне фазы 380 В)

Выбраны тырыстар 1500A/1600V з магутнасцю ад 500кВт да 750кВт. (Напружанне фазы 380 В)

Выбраны тырыстар 1500A/2500V з магутнасцю ад 800кВт да 1000кВт. (Напружанне фазы 660 В)

Выбраны тырыстар ток 2000A/2500V з магутнасцю 1200KW-1600KW. (Напружанне фазы 660 В)

Выбраны тырыстар 2500A/3000V з магутнасцю ад 1800кВт да 2500кВт. (Напружанне фазы 1250 В)