site logo

Kedu otu esi ahọrọ thyristor inverter maka ọkụ ọkụ induction?

How to choose inverter thyristor for induction ọkụ na-agbaze?

1) Họrọ dị ka usoro ugboro ole na-arụ ọrụ nke ọkụ ọkụ induction;

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) Họrọ dị ka mmepụta ike nke induction agbaze ọkụ;

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

Thyristor 300A/1400V ahọpụtara nwere ike n’etiti 50KW na 100KW. voltaji na-agba ọsọ (380V)

Thyristor 500A/1400V ahọpụtara nke nwere ike nke 100KW-250KW. (380V voltaji na-agba ọsọ)

Thyristor 800A/1600V ahọpụtara nke nwere ike sitere na 350KW ruo 400KW. voltaji na-agba ọsọ (380V)

Thyristor 1500A/1600V ahọpụtara nwere ike n’etiti 500KW na 750KW. voltaji na-agba ọsọ (380V)

Thyristor 1500A/2500V ahọpụtara nwere ike n’etiti 800KW na 1000KW. voltaji na-agba ọsọ (660V)

Thyristor 2000A/2500V ahọpụtara nke nwere ike nke 1200KW-1600KW. (660V voltaji na-agba ọsọ)

Thyristor 2500A/3000V ahọpụtara nwere ike n’etiti 1800KW na 2500KW. voltaji na-agba ọsọ (1250V)