1) Sélectionnez en fonction de la plage de fréquence de fonctionnement du four de fusion à induction ;

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) Sélectionnez en fonction de la puissance de sortie du four de fusion à induction ;

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

Le thyristor actuel 300A/1400V sélectionné avec une puissance comprise entre 50KW et 100KW. (tension de phase 380V)

Le thyristor actuel 500A/1400V sélectionné avec une puissance de 100KW-250KW. (tension phase-in 380V)

Le thyristor actuel 800A/1600V sélectionné avec une puissance allant de 350KW à 400KW. (tension de phase 380V)

Le thyristor actuel 1500A/1600V sélectionné avec une puissance comprise entre 500KW et 750KW. (tension de phase 380V)

Le thyristor actuel 1500A/2500V sélectionné avec une puissance comprise entre 800KW et 1000KW. (tension de phase 660V)

Le thyristor actuel 2000A/2500V sélectionné avec une puissance de 1200KW-1600KW. (tension phase-in 660V)

Le thyristor actuel 2500A/3000V sélectionné avec une puissance comprise entre 1800KW et 2500KW. (tension de phase 1250V)