- 06
- Apr
Come scegliere il tiristore inverter per il forno fusorio a induzione?
How to choose inverter thyristor for forno fusorio ad induzione?
1) Selezionare in base alla gamma di frequenza operativa del forno fusorio ad induzione;
The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.
The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.
The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.
KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.
The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.
2) Selezionare in base alla potenza di uscita del forno fusorio ad induzione;
According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.
Il tiristore selezionato corrente 300A/1400V con potenza tra 50KW e 100KW. (tensione di fase di 380V)
Il tiristore selezionato corrente 500A/1400V con una potenza di 100KW-250KW. (tensione di fase di 380 V)
La corrente selezionata tiristore 800A/1600V con una potenza che va da 350KW a 400KW. (tensione di fase di 380V)
Il tiristore selezionato corrente 1500A/1600V con potenza tra 500KW e 750KW. (tensione di fase di 380V)
Il tiristore selezionato corrente 1500A/2500V con potenza tra 800KW e 1000KW. (tensione di fase di 660V)
Il tiristore selezionato corrente 2000A/2500V con una potenza di 1200KW-1600KW. (tensione di fase di 660 V)
Il tiristore selezionato corrente 2500A/3000V con potenza tra 1800KW e 2500KW. (tensione di fase di 1250V)