site logo

इंडक्शन मेल्टिंग फर्नेससाठी इन्व्हर्टर थायरिस्टर कसे निवडावे?

How to choose inverter thyristor for प्रेरण वितळण्याची भट्टी?

1) इंडक्शन मेल्टिंग फर्नेसच्या ऑपरेटिंग वारंवारता श्रेणीनुसार निवडा;

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) इंडक्शन मेल्टिंग फर्नेसच्या आउटपुट पॉवरनुसार निवडा;

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

निवडलेला वर्तमान 300A/1400V थायरिस्टर 50KW आणि 100KW मधील पॉवरसह. (380V फेज-इन व्होल्टेज)

500KW-1400KW क्षमतेसह निवडलेला वर्तमान 100A/250V थायरिस्टर. (380V फेज-इन व्होल्टेज)

निवडलेला वर्तमान 800A/1600V थायरिस्टर 350KW ते 400KW पर्यंतच्या पॉवरसह. (380V फेज-इन व्होल्टेज)

निवडलेला वर्तमान 1500A/1600V थायरिस्टर 500KW आणि 750KW मधील पॉवरसह. (380V फेज-इन व्होल्टेज)

निवडलेला वर्तमान 1500A/2500V थायरिस्टर 800KW आणि 1000KW मधील पॉवरसह. (660V फेज-इन व्होल्टेज)

2000KW-2500KW क्षमतेसह निवडलेला वर्तमान 1200A/1600V थायरिस्टर. (660V फेज-इन व्होल्टेज)

निवडलेला वर्तमान 2500A/3000V थायरिस्टर 1800KW आणि 2500KW मधील पॉवरसह. (1250V फेज-इन व्होल्टेज)