site logo

इन्डक्शन पग्लने फर्नेसको लागि इन्भर्टर थायरिस्टर कसरी छनौट गर्ने?

How to choose inverter thyristor for इन्डक्शन पिघलने भट्टी?

1) इन्डक्शन पिघलने भट्टीको अपरेटिङ फ्रिक्वेन्सी दायरा अनुसार चयन गर्नुहोस्;

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) इन्डक्शन पिघलने भट्टीको उत्पादन शक्ति अनुसार चयन गर्नुहोस्;

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

चयन गरिएको वर्तमान 300A/1400V thyristor 50KW र 100KW बीचको शक्तिको साथ। (३८०V फेज-इन भोल्टेज)

चयन गरिएको वर्तमान 500A/1400V thyristor 100KW-250KW को शक्ति संग। (380V फेज-इन भोल्टेज)

चयन गरिएको वर्तमान 800A/1600V thyristor 350KW देखि 400KW सम्मको पावरको साथ। (३८०V फेज-इन भोल्टेज)

चयन गरिएको वर्तमान 1500A/1600V thyristor 500KW र 750KW बीचको शक्तिको साथ। (३८०V फेज-इन भोल्टेज)

चयन गरिएको वर्तमान 1500A/2500V thyristor 800KW र 1000KW बीचको शक्तिको साथ। (३८०V फेज-इन भोल्टेज)

चयन गरिएको वर्तमान 2000A/2500V thyristor 1200KW-1600KW को शक्ति संग। (660V फेज-इन भोल्टेज)

चयन गरिएको वर्तमान 2500A/3000V thyristor 1800KW र 2500KW बीचको शक्तिको साथ। (३८०V फेज-इन भोल्टेज)