Как да изберем инверторен тиристор за индукционна топилна пещ?

How to choose inverter thyristor for индукционна топилна пещ?

1) Изберете според работния честотен диапазон на индукционната топилна пещ;

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) Изберете според изходната мощност на индукционната топилна пещ;

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

Избраният ток 300A/1400V тиристор с мощност между 50KW и 100KW. (380V входно напрежение)

Избраният ток 500A/1400V тиристор с мощност 100KW-250KW. (380V входно напрежение)

Избраният ток 800A/1600V тиристор с мощност от 350KW до 400KW. (380V входно напрежение)

Избраният ток 1500A/1600V тиристор с мощност между 500KW и 750KW. (380V входно напрежение)

Избраният ток 1500A/2500V тиристор с мощност между 800KW и 1000KW. (660V входно напрежение)

Избраният ток 2000A/2500V тиристор с мощност 1200KW-1600KW. (660V входно напрежение)

Избраният ток 2500A/3000V тиристор с мощност между 1800KW и 2500KW. (1250V входно напрежение)