- 06
- Apr
Ako si vybrať invertorový tyristor pre indukčnú taviacu pec?
How to choose inverter thyristor for indukčná taviaca pec?
1) Zvoľte podľa rozsahu prevádzkovej frekvencie indukčnej taviacej pece;
The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.
The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.
The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.
KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.
The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.
2) Zvoľte podľa výstupného výkonu indukčnej taviacej pece;
According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.
Zvolený prúdový 300A/1400V tyristor s výkonom medzi 50KW a 100KW. (380V fázové napätie)
Zvolený prúdový 500A/1400V tyristor s výkonom 100KW-250KW. (380V fázové napätie)
Zvolený prúdový 800A/1600V tyristor s výkonom od 350KW do 400KW. (380V fázové napätie)
Zvolený prúdový 1500A/1600V tyristor s výkonom medzi 500KW a 750KW. (380V fázové napätie)
Zvolený prúdový 1500A/2500V tyristor s výkonom medzi 800KW a 1000KW. (660V fázové napätie)
Zvolený prúdový 2000A/2500V tyristor s výkonom 1200KW-1600KW. (660V fázové napätie)
Zvolený prúdový 2500A/3000V tyristor s výkonom medzi 1800KW a 2500KW. (1250V fázové napätie)