څنګه د انډکشن خټکي فرنس لپاره انورټر تایریسټور غوره کړئ؟
How to choose inverter thyristor for د انډکشن خټکي کوره؟
1) د انډکشن خټکي فرنس د عملیاتي فریکونسۍ سلسلې سره سم انتخاب کړئ؛
The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.
The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.
The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.
KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.
The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.
2) د انډکشن خټکي فرنس د تولید ځواک سره سم انتخاب کړئ؛
According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.
ټاکل شوی اوسنی 300A/1400V thyristor د 50KW او 100KW ترمنځ بریښنا سره. (380V پړاو ولتاژ)
ټاکل شوی اوسنی 500A/1400V thyristor د 100KW-250KW بریښنا سره. (380V پړاو ولتاژ)
ټاکل شوی اوسنی 800A/1600V تایریسټر د 350KW څخه تر 400KW پورې بریښنا سره. (380V پړاو ولتاژ)
ټاکل شوی اوسنی 1500A/1600V thyristor د 500KW او 750KW ترمنځ بریښنا سره. (380V پړاو ولتاژ)
ټاکل شوی اوسنی 1500A/2500V thyristor د 800KW او 1000KW ترمنځ بریښنا سره. (660V پړاو ولتاژ)
ټاکل شوی اوسنی 2000A/2500V thyristor د 1200KW-1600KW بریښنا سره. (660V پړاو ولتاژ)